Home>ASME standards list>ASME A112.18.9 pdf free download

ASME A112.18.9 pdf free download

ASME A112.18.9-2011 pdf free download.Protectors/ Insulators for Exposed Waste and Supplies on Accessible Fixtures.
This Standard shall show material and performance specifications and use of protectors/insulators for exposed waste and supplies for public/commercial and private/residential buildings using product covered under this Standard.
This Standard is intended to also cover products that will satisfy the requirements of ICC/ANSI A117.1, Standard for Accessible and Usable Buildings and Facilities for Persons With I’hysical Disabilities, and to establish a generally acceptable performance standard for protectors/insulators for exposed waste and supplies, so a physically challenged person will be protected when using a sink or lavatory in a public/commercial or private/residential facility.
1.2 Units of Measurements
Values are generally stated in U.S. Customary units and International System of Units (SI). US. Customary units shall be considered as the standard.
2 DEFINITIONS
acce.csibk fixture: a plumbing fixture that complies with the requirements of ICC/ANSI A117.l, Standard for Accessible and Usable Buildings and Facilities for Persons With Physical Disabilities.
prokctors/insulators: individual covers over waste and supply pipes that isolate them to prevent injury from contact with hot, cold, or sharp surlaces.
supplies: the exposed water pipes to a fixture fitting consisting of stop valves and riser tubing under a sink or lava tory.
voids: any unprotected area of exposed waste and supplies that could contact the user.
waste: standard drains with tailpieces and P-traps, standard drains with tailpieces and bottle traps, or offset drains using 90-deg elbows, horizontal legs, vertical tail- pieces, and P-traps.
3 REFERENCES
The following is a list of publications referenced in this Standard.
ASTM G21, Standard rractice for Determining Resistance of Synthetic Polymeric Materials to Fungi
Publisher: American Society for Testing and Materials
(ASTM International), flX) Barr Harbor Drive, P.O. Box
C700, West Conshohocken, PA 19428-2959
(www.astm.org)
ICC/ANSI A117.1, Standard for Accessible and Usable Buildings and Facilities for Persons With Physical Disabilities’
Publisher: International Code Council (ICC), 500 New Jersey Avenue, NW, Washington, DC 2000] (www.iccsafe.org)
4 DESIGN REQUIREMENTS
4.1 GeneraL Requirements
Trap protectors/insulators shall be designed to fit the specified size of the trap. A single size trap protector/ insulator shall be permitted to accommodate multiple sizes of traps: 11/4 in., as well as I !4 in. or 2 in, nominal. Field-applied protectors/insulators shall have enough fasteners to securely fasten the protectors/insulators over the drain pipe assemblies, water supply risers, and stops. A fastener consisting of a single, continuous seam shall also be acceptable. Fasteners shall not present sharp or abrasive external surfaces. Devices covered by this Standard shall be removable, reusable, and after reassembly meet the requirements of this Standard.
4.2 Heat Transfer
Protectors/insulators for exposed waste and supplies shall be engineered to comply with the heat transfer requirements contained in para. 51.
4.3 WorkmanshIp
lxterior surfaces of protectors/insulators for exposed waste and supplies exterior surface shall be smooth and water resistant, having no sharp or abrasive features or protrusions.ASME A112.18.9 pdf download.