ASME B16.1-2010 pdf free download.Gray lron Pipe Flanges and Flanged Fittings Classes 25, 125, and 250.
Equipment shall be designed to produce wall thicknews given In the tables Wall thickness at no point shall be les, than 873% of the thickness given in the tables
7.2 FacIng
(a) Gasses 25 and 125 gray iron flanges and flanged fittings shall be flat faced (i.e., without proectlon or raiscd face) and finished n accordance with MSS SP-6.
(b) Class 250 flanges and flanged fittings shall have a 2 mm (0.06 in.) raised face of the diameters given in Table 2 and finished in acconiance with MSS SP-6. The raised face is included in the minimum flange thickness and center-to-face dimension.
13 Center-to-Face Dimensions
7.3.1 Side Outlet Fittings. Side outlet elbows, side outlet tees, and side outlet crows shall have all openings on intersecting centerlines. Long-radius elbows with side outlet shall have the side outlet on the radial centerline of the elbow.
7.3.2 Elbows
(a) The center-to-face dimensions for straight-size 90-deg elbows, 90-deg tong-radius elbows, 45-deg elbows, side-outlet 90-deg elbows, and double-branch elbows are shown in Tables 3,4, and 5.
(b) Reducing 90-deg elbows, reducing 90-deg long- radius elbows, reducing side-outlet 90-deg elbows, and reducing double-branch elbows shall have the same center-to-face dimensions as straight-size fittings shown in Tables 3, 4, and 5 corresponding to the size of the largest opening.
(c) For 90-deg long-radius elbows with side outlet, the center-to-face dimensions of the side outlet shall be the same as dimension A in Tables 3, 4, and 5 for a straight-size 90-deg elbow corresponding to the size of the largest opening.
(d) Special-degree elbows ranging from I deg to 45 deg,. inclusive, shall have the same center-to-face dimensions as those for 45-deg elbows; those over 45 deg and up to 90 deg. inclusive, shall have the same center- to-lace dimensions as tho,e for 90-deg elbows. The angle designation of an elbow is the angle between the flange faces.
7.3.3 Tees, Crosses, and Laterals
(a) The center-to-face dimensions for straight-size tees and crosses, with or without side outlet, and laterak are shown in Thbles 3,4, and 5.
(b) Reducing tees and reducing aoeses, with or without side outlet, and reducing laterals, NI’S 16 and smaller, shall have the same center-to-face dimensions as straight-size fittings shown in Tables 3,4, and 5 corresponding to the size of the largest opening. For M’S 18 and largest. if the outlet of a reducing tee; the branch of a reducing lateral; or the largest outlet of a reducing side outlet tee, reductng cross, and reducing side outlet cross is the same size or smaller than given in Tables 3,4, and 5 (short body pattern), the center-to-face dimensions shown in these Tables shall be used. If a branch or any outlet Is larger than shown in Tables 3, 4, and 5, the center-to-lace dimensions shall be the same as for the straight-size fitting shown in Thbles 3. 4, and 5 corresponding to the size of the largest opening. Tees, crosses, and laterals, reducing on the run only, shall have the same center-to-face dimensions as straight-size fittings shown in Tables 3,4. and 5 corresponding to the size of the largest opening.
(C) Tees reducing on both nina are generally known as bull-head tees and have the same center-to-lace dimensions as straight-size fittings corresponding to the size of the outlet.
7.3.4 True Y’s. Center-to-face dimensions for straight-size true Ys are shown in Tables 4 and 5. Reducing sizes are considered special and should be made to suit conditions.
7.3.5 Reducers and Eccentric Reducers. The face- to-face dimensions for all reductions of reducers and eccentric reducers shall be the same as given in Thbks 4 and 5 for the largest opening.
7.4 Center-to-Face Tolerances
The loUowing tolerances shall be permitted on all center-to-contact surface dimensions of fithngs Tolerances for contact surface-to-contact surface dimensions shall be twice those given below. The largest opening in the fitting governs the tolerance to be applied to all openings.ASME B16.1 pdf download.